Circulation. Utility of a power aspiration-based extraction technique as an initial and secondary approach in the treatment of peripheral arterial thromboembolism: results of the multicenter PRISM trial. Lightning has also demonstrated an 18:1 potential fluid loss savings during bench top testing when used versus the Dynamic Aspiration Tubing. Siena, Italy
Disclosures: None. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove the thrombus. All Rights Reserved Privacy Policy, With Frank R. Arko III, MD; Patrick E. Muck, MD, RVT, FACS; Ripal T. Gandhi, MD, FSIR, FSVM; Robert Lookstein, MD, MHCDL, FSIR, FAHA, FSVM; Michael S. Rosenberg, MD, FSIR, FACR; Eric Moldestad, MD; Gianmarco de Donato, MD; Thomas S. Maldonado, MD; D. Chris Metzger, MD, Robert Lookstein, MD, MHCDL, FSIR, FAHA, FSVM. The continuously powered engine pump , which is activated by a single touch, achieves a negative suction pressure of 29 inHg, a nearly pure vacuum. Precautions The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. Department of Medicine, Surgery and Neuroscience
Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. If the cause cannot be determined, withdraw the device or system as a unit. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Percutaneous manual thromboaspiration was the first technique proposed, followed by a series of percutaneous mechanical thrombectomy devices based on a different mechanism of action (mechanical fragmentation, aspiration, rheolytic thrombectomy, and their combinations). Blood clots in the lungs can block the lungs from absorbing oxygen, causing strain on the heart and other organs. J Vasc Interv Radiol. For more information, visit https://www.penumbrainc.com/indigo-lightning/. Robert Lookstein, MD, MHCDL, FSIR, FAHA, FSVM
There may be additional risks of which we are not presently aware or that we currently believe are immaterial which could have an adverse impact on our business. Lightning 12 combines the new Indigo System CAT12 Aspiration Catheter with Lightning Intelligent Aspiration, enabling physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism . Penumbra continues to lead the field of clot management by bringing highly innovative technology to address the challenges that we as physicians face while caring for our patients, commented Frank Arko, MD, in the company's announcement. Do not resterilize or reuse. The Indigo System with Lightning Intelligent Aspiration and Separators is indicated for the removal of fresh, soft emboli and thrombi from the peripheral arterial and venous . INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. Figure 1 shows a popliteal aneurysm with massive endoluminal thrombosis and distal multilevel embolism in the tibial and plantar arteries. INDIGO Aspiration System Indication for Use Otherwise, this could result in degradation of the performance of this equipment. Return all damaged devices and packaging to the manufacturer/distributor. Figure 8. A venogram was performed via left popliteal vein access, which demonstrated thrombosis of the left femoral vein (FV) and common femoral vein (CFV) (Figure 1) and the previously stented left common iliac vein (CIV) and external iliac vein (EIV) (Figure 2). Made of laser-cut hypotube technology, CAT7 and CAT12 are designed to increase trackability and torqueability. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia; arteriovenous fistula; cardiac injury; cardio-respiratory arrest; death; device malfunction; distal embolization; emboli; excessive blood loss; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; hemoptysis; respiratory failure; thromboembolic events. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature.
The Next Generation of Thrombus Removal | Penumbra Inc The patient had a history of lower left extremity venous thrombus dating back to 2013, with chronic residual nonocclusive popliteal vein thrombus in 2018. Precautions The device is intended or single use only. The patients left leg was cool to the touch with signs of paresthesia but with motor function still intact. After adjunctive endovascular (angioplasty, stenting, or lysis), TIMI 2-3 was reached in up to 95.3% of patients. Prior to use, please refer to the . 2011;17:283-289. doi: 10.4261/1305-3825.DIR.3687-10.2, 3.