Any powered dispensing nozzles used are of the automatic-closing type. (C) The date (month, year) of the tests and inspections. Special Permit is valid for 2.5 years from date of manufacturing. Only designated persons shall conduct fueling operations. 49 CFR CH.III 7.4.5. The details of the DOT 406 specification can be found in 49 CFR 178 sub-parts 345 and 346. You can learn more about the process The threads of all fittings must be Dryseal American Standard Taper Pipe Thread or Dryseal SAE Short Taper Pipe Thread, specified in Society of Automotive Engineers Standard J476, as contained in the 1971 edition of the SAE Handbook, except that straight (nontapered) threads may be used on fittings having integral flanges and using gaskets for sealing. ATTA, Inc. must receive documentation of retesting within the 2.5 years limit to maintain ATTA, Inc. manufacture warranty. (i) The IBC must be internally inspected for cracks, warpage, and corrosion or any other defect that might render the IBC unsafe for transportation. Fuel leaking from a rollover valve on a gravity fed system would be in close proximity to the DPF and the possibility of fire is significant. This means safety cans or containers need to be approved by the Department of Transportation (DOT). The bottom of the L-shape fits under most standard toolboxes. (iii) The proper functioning and leak tightness of the service equipment, if applicable, is verified. Copyright Transfer Flow, Inc. All rights reserved, American-Made Fuel Systems Engineered for Excellence Since 1983, Fuel tanks are baffled to prevent fuel slosh, Meets emissions regulations of the California Air Resources Board, U.S. Department of Transportation (DOT) and Environment Protection Agency (EPA), Meet California Air Resources Board and EPA requirements concerning fuel fill rates and regulations, Meet the fastener (strap) regulations specified by the American National Standards Institute (ANSI) and National Fire Protection Association (NFPA) and required by the Recreation Vehicle Industry Association (RVIA), Designed using, as a minimum, high-yield 14-gauge aluminized ReliaSteel, Liquid-filled fuel tanks are subjected to a 30-foot drop test, and cannot leak, Refueling tanks are designed to be mounted near the head gate in a pickup box, flat bed or utility box (no other location on the pickup or truck is recommended), Transfer Flow refueling tanks must be attended to at all times during loading and unloading by a qualified person as described respectively in 49 CFR 177.834 (i), (3), and (4), Refueling tanks must be retested every 2 1/2 years in accordance with 49 CFR 180.352, Transfer Flows DOT Special Permit SP-11911 is supplied with every refueling tank, and must be carried aboard each vehicle using a refueling tank. Different guidelines apply for handling liquids at point of final use (see below). (10) Air vent. Choose Aluminum Tank Industries for top quality fuel tanks that will hold up to the toughest conditions and also for your peace of mind. Requirements for retest and inspection of IBCs. - eCFR DOT Regulations for Mobile Fuel Containers. 49 CFR 172.101 "Published Edition". Fill the tank three-fourths full with fuel, seal the fuel feed outlet, and invert the tank. During regeneration, many DPF units reach temperatures of 600C (1,112F). We have given you 5 of the rules that apply to this issue. You must have at least one fire extinguisher within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication in the area. Liquid fuels not handled by pump shall be handled and transported only in portable containers or equivalent means designed for that purpose. The DOT has issued Transfer Flow DOT Special Permit SP-11911 to manufacture and sell refueling tanks that can store gas, diesel, ethanol, methanol, kerosene and aviation fuel. (iii) If a fuel tank has drains the drain fittings must permit substantially complete drainage of the tank. Flammable and combustible liquids should always be kept in approved storage containers when not in use. (i) Procedure. Click HERE to see all GPI and GPRO Fuel Transfer Pumps. Except for diesel fuel tanks, the fittings through which fuel is withdrawn from a fuel tank must be located above the normal level of fuel in the tank when the tank is full. This is an automated process for DOT Requirements Flammable liquids may be dispensed in the open from a tank or from other vehicles equipped for delivering fuel to another vehicle only if: Dispensing hoses do not exceed 50 feet (15.24 m) in length; and. DOT HAZMAT regulations. Wheels: Polished aluminum wheels are installed for a beautiful shine and rust prevention. All fuel tanks must be installed per instructions with no exceptions. user convenience only and is not intended to alter agency intent Do not weld or torch any fuel tank or fuel system component. Another consideration is tank pressure. At least four full threads must be in engagement in each fitting. (5) A gasoline tank, other than a side-mounted gasoline tank, manufactured before January 1, 1973, and mounted on a vehicle other than a bus must conform to the rules in paragraphs (c) (1) through (10), inclusive, of this section. Use the form below to enter your vehicle details. This document is available in the following developer friendly formats: Information and documentation can be found in our For safety reasons, only approved closed containers of a maximum capacity of five gallons can be used. 4. Valves and connections shall be protected from contact damage. No welding or cutting with torches can go on nearby.